1) Use high-precision, large range imported electronic flow sensors and pressure sensors to accurately measure the resistance performance of cigarettes.
2) One click testing, once the sample is installed, it can be quickly tested with just one button. The instrument comes with a USB interface, and the accompanying software can be used to statistically analyze and print standard test reports. The test report can also be saved in EXCEL format. The machine is equipped with a micro printer that can print in real-time
3) Compact structure, space saving design, easy to use.
4) Adopting touch screen control, with good human-computer interaction and simple operation
5) Equipped with an airbag clamping mechanism, one click clamping of the sample ensures better sealing without damaging the filter rod. The testing structure is accurate and consistent with the results of the comprehensive testing platform.
6) Standard filter rods with calibration certificates from tobacco research institutes can be optionally selected
7) Equipped with a flow controller, different filter rods can still maintain accurate gas flow rate.
8) An independent negative pressure control system ensures the stability of negative pressure, thereby guaranteeing the stability of test results.
1) Measure the suction resistance of filter rods and conventional cigars for tobacco production quality control and tobacco inspection.
2) Testing principles and criteria:
When simulating the smoking action of a person on a cigarette and inhaling a fixed flow rate of 17.5ml/s of air, a certain vacuum pressure will be generated at the suction end of the cigarette, which is the suction resistance, abbreviated as suction resistance This machine is based on the standards JJG (Tobacco) 15-2010, GB/T 22838.5-2009 Determination of physical properties of cigarettes and filter rods Part 5: Cigarette suction resistance and filter rod pressure drop.
Measurement range: | 0~10Kpa |
Resolution: | ±10Pa |
Error: | <1% |
Testing time: | About 10 seconds |
Test port inner diameter: | 16~20mm (can be customized according to customer requirements) |
Test port depth: | 9mm |
Computer communication: | USB or RS485 |
Fixed airflow velocity: | 17.5ml/s |
Sample clamping method: | Automatic airbag clamping |
Pressure sensor: | Negative pressure sensor |
Intake pressure control system: | 1 set |
Standard filter rod: | One verification stick |
power supply | 220V 50HZ (foreign countries need to inform the power requirements in advance) |